Poured Socket Connections

A typical poured socketed connection on a counterweight rope.

Failure of a poured socket counterweight connection is obviously a concern of ski area lift maintenance personnel — as well as of lift inspectors — but there is not that much awareness of how to check and what to check. At the outset I should define “failure.” To the area operator it means a connection that has actually parted, and fortunately, this is extremely rare. But to the lift inspector, failure has to mean a socket that has had to be replaced for what-ever reason whatsoever, and for the purposes of this article we use that meaning.

Counterweight sockets of the poured type generally fail for one of two basic reasons: 1) improper original construction; and 2) breakage of the counterweight wire rope at the entrance to the socket.