The Voice of the Mountain Resort Industry  |  Est. 1962

Advertisement

Pro Deals Leaderboard

September 1979 Issue

Magnetic Particle Inspection

Caustic cleaning of grips prior to the inspection.

In the last issue of SAM (Summer 79), we discussed the most basic of all NDT methods, Liquid Penetrant testing. Although comparatively simple compared to the other types of testing, LPT was shown to have numerous limitations. It will not indicate sub-surface “discontinuites” nor will it allow testing in cold temperatures. In addition, the dwell times involved in “penetrant” drying after removal and initial penetration are critical. Finally, LPT may not disclose tight discontinuities which may be potential “defects”.

Caustic cleaning of grips prior to the inspection.
Caustic cleaning of grips prior to the inspection.

Advertisement

Pro Deals Billboard