The Voice of the Mountain Resort Industry  |  Est. 1962

Advertisement

Mountains Don’t Move Themselves

March 1980 Issue

Shaft Safety In Chairlift Gearboxes

Ed. Note: SAM is happy to publish the following technical article on an important subject. We do so in the knowledge that there may be a measure of disagreement with some of Dr. Kissling's ideas, especially on non-destructive testing.

The size of transmission shafts for ski and chair lift gear assemblies did not become a critical issue until the late fifties. Previously, the drive sheave had nearly always been engaged with an open gear transmission and thus rotated around a rigid shaft. With the introduction of closed drive units with cantilevered sheaves on stub shafts, the problem of transmission shaft safety gained significance. Initially, a minimum static safety factor of 5 was considered satisfactory. Soon, however, engineers realized that they were dealing with a fatigue strength problem which required an entirely different approach. The new types of transmission shafts were subject to a composite alternating bending and torsional stress. The literature available at that time was rather vague and did not supply any tangible figures. In his publication “Maschinenelemente“, G. Niemann had given experimental data but the results were not sufficient for reliable interpolation, let alone extrapolation.

When the 3rd edition of “Neue Festigkeitsberechnung fur den Maschinenbau” by Hanchen & Decker was published in 1967, it finally became possible to implement detailed calculations. The author described the respective calculation method in a 1973 issue of SAM.

Advertisement

Creative Design Billboard