The Voice of the Mountain Resort Industry  |  Est. 1962

Advertisement

Outside Is Where We Thrive – Summer

Summer 1978 Issue

Chairlift Deropements

“. . . On both hold-down and support sheaves, suitable devices shall be installed and maintained that will stop the lift in case of deropement . . .”

Doppelmayr version of breakable link switch

The above sentence is quoted from ANSI (American National Standards Institute) B-77.1-1976 Standard, Article 2.3.3.1.2, Page 30, which defines safety requirements for aerial passenger tramways. As the “B-77 Standard” has been adopted by a large number of state authorities, the U.S. Forest Service, and the two major ski lift insurance carriers in the United States. as their governing standard, the stipulated requirements thus need to be adhered to. An almost identical requirement is part of the Canadian equivalent, the CSA (Canadian Standards Association) Z-98 Standard.

Interestingly, although these standards went to great lengths of detail about some aspects of lift or aerial tramway design, certain essential (but possibly controversial) aspects of lift design are passed over in one generalized statement, as is the one quoted here. This statement is in obvious reference to what, is commonly referred to as the “tower derail (or deropement) safety switch.” Thus the standards do not say what type of “suitable device,” where or how it should be mounted, or how it is to sense the “case of deropement.” Those individuals who are intimately involved with the design, operation and maintenance of lifts, are, however, keenly aware that this generalized statement packs a broad scope of interpretations.